Comprehensive analysis of gas alarm purchase method

The purchase of gas alarms depends on what products are purchased. The alarm products can be divided into five categories, namely: gas alarm controllers, combustible gas detectors, toxic gas detectors, household gas alarms, imported gas alarms, portable gas Detectors, gas emergency cut-off valves, insulating flanges, positive pressure air breathing apparatus and other products. Here is a list of products according to classification for your reference.
1. Combustible gas alarm
As the leading product in gas alarms, combustible gas detection alarms are widely used in various industrial production and other occasions. The main series of products are:
RB-KYII gas alarm controller, RB-TZ point gas detector, RB-TT point gas detector. Detectable gases include: natural gas, liquefied gas, coal gas, ethane, acetylene, butane, n-butane, isobutane, pentane, hexane, halogenated hydrocarbons (chloromethane, methylene chloride, trichloride) Ethane, vinyl chloride), alcohols (methanol, ethanol, propanol), ethers, ketones (butanone, acetone), hydrogen, toluene and other compounds (petrol, industrial solvents, paints, thinners, coolants, dry cleaning fluid , Methyl acetate, etc.).
2. Toxic gas alarm
Toxic gas alarms are mainly used to detect CO, lǜ and other harmful gases. The main products are RB-KY universal gas alarm controller, RB-TZ toxic gas detector. Detectable gases include: co, gas, hydrogen sulfide, phosphine, qíng hydrogen, nitric oxide, nitrogen dioxide, formaldehyde and other toxic and harmful gases.
3. Household gas and gas alarm
The gas alarms of the household series are low in price and can only be used for daily home life. They are generally installed in the kitchen close to places where gas and natural gas leakage may occur. The main products are: RB-â…¡ independent gas detectors.
4. Imported alarm
At present, domestic gas alarms are enough to meet the needs of industrial production safety. Imported gas alarms are introduced to meet the needs of different customers. The hot-selling brand is the US Honeywell ImpulseXP portable single gas detector. There are also a variety of ImpulseX4 composite gas detectors available for purchase.
5. Portable gas detector
The portable gas detector is mainly used for occasions that are not suitable for fixed installation or temporary detection needs. The main features are convenient portability and more flexible detection. For example, mines, cave explorations, etc. should be prepared. Enter concentration detection to ensure personal safety, the main products are SQJ-1A portable gas detector, SQJ-IIIAII portable gas detector.
Since each gas has its own parameters and technical requirements, we will not list them one by one here. You can choose the appropriate gas alarm according to the detected gas and the occasion of use.

Closed Cooling Tower

Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.

First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.

Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.

Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.

To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.

Closed Cooling Tower,Closed Circuit Cross Flow,Closed Loop Cooling Tower,Closed Circuit Cooler