Refrigeration Type R134A Electronic Expansion Valve

Pressure: Ordinary Temperature
Valve Structure: Pilot Piston Structure
Power Supply: AC Solenoid Valve
Usage: Safety, Emptying, Drain, Temperature Control, Flow Control
Trademark: Royals Technology
Transport Package: Wooden Box
Origin: Qingdao
Pressure: Ordinary Temperature
Valve Structure: Pilot Piston Structure
Power Supply: AC Solenoid Valve
Usage: Safety, Emptying, Drain, Temperature Control, Flow Control
Trademark: Royals Technology
Transport Package: Wooden Box
Origin: Qingdao

Refrigeration Type R134A Electronic Expansion Valve



Production Description:

Electronic expansion valves are designed for usage in air conditioning and refrigeration systems or in heat pumps. The valve supports automatic adjustment of refrigerant flow rate and makes the system work under optimized conditions for the purpose of fast cooling or heating, precise temperature control and energy saving. The valve can also be used e.g. for suction line pressure controls. These valves provide bidirectional operation to control the refrigerant flow rate in heating or cooling mode. 

Refrigeration Type R134A Electronic Expansion Valve
Refrigeration Type R134A Electronic Expansion Valve
 

Feature:

Applicable for oil-free system (T series)

Smaller installation space: low height, small volume, light weight

Optimized flow path design for noise reduction

Fast operation, Energy saving

Applicable for reversible systems like heat pumps: bidirectional flow

Refrigeration Type R134A Electronic Expansion Valve
 

Specification:

Applicable refrigerants: R22, R134A, R404A, R407C, R410A, R507A etc.

Cooling Capacity: 3,5 to 105 kW (R22 Nominal Capacity)

Medium temperature: -30C to +70C (duty cycle rate below 50%)

Ambient temperature: -30C to +60C (duty cycle rate below 50%)

Relative humidity: below 95% RH

Ps: 4.5MPa (45 Bar)

Installation position: Coil upwards, valve rotor central axis within +/-15 versus vertical axis

500 steps (full stroke); 32 20 opening steps

Certifications: UL/CSA and declaration according to LVD or PED

  Model

   Port Size

 

Nominal Capacity

         (KW)

 

 

Max  W.P

Max  

O.P.D

Max 

R.O.P.D

(mm)

R22

R134a

R407C

R404A/R507A

R410A

(Mpa)

(Mpa)

(Mpa)

DPF(Q)1.3-01

1.3

3.5

2.7

3.5

2.5

4.2

4.2

3.43

≥2.1

DPF(Q)1.65-01

1.65

5.3

4.1

5.3

3.7

6.36

4.2

3.43

≥2.1

DPF(Q)1.8-01

1.8

7

5.4

7

4.9

8.4

4.2

3.43

≥2.1

DPF(Q)2.0-01

2

8.75

6.7

8.75

6.1

10.5

4.2

3.43

≥2.1

DPF(T)1.3-01

1.3

3.5

2.7

3.5

2.5

4.2

4.2

3.43

≥2.1

DPF(T)1.65-01

1.65

5.3

4.1

5.3

3.7

6.36

4.2

3.43

≥2.1

DPF(T)1.8-01

1.8

7

5.4

7

4.9

8.4

4.2

3.43

≥2.1

DPF(T)2.0-01

2

8.75

6.7

8.75

6.1

10.5

4.2

3.43

≥2.1

DPF(T)2.2-01

2.2

10.5

8.1

10.5

7.4

12.6

4.2

3.43

≥2.1

DPF(T)2.4-01

2.4

17.5

13.5

17.5

12.3

21

4.2

3.43

≥2.1

DPF(T)3.0-02

3

21

16.2

21

14.7

25.2

4.2

3.43

≥1.5

DPF(T)3.2-02

3.2

28

21.6

28

19.6

33.6

4.2

3.43

≥1.5

DPF(H)3.0-02

3

21

16.2

21

14.7

25.2

4.2

3.43

≥1.5

Refrigeration Type R134A Electronic Expansion Valve

Refrigeration Type R134A Electronic Expansion Valve

Refrigeration Type R134A Electronic Expansion Valve



Production Description:

Electronic expansion valves are designed for usage in air conditioning and refrigeration systems or in heat pumps. The valve supports automatic adjustment of refrigerant flow rate and makes the system work under optimized conditions for the purpose of fast cooling or heating, precise temperature control and energy saving. The valve can also be used e.g. for suction line pressure controls. These valves provide bidirectional operation to control the refrigerant flow rate in heating or cooling mode. 

Refrigeration Type R134A Electronic Expansion Valve
Refrigeration Type R134A Electronic Expansion Valve
 

Feature:

Applicable for oil-free system (T series)

Smaller installation space: low height, small volume, light weight

Optimized flow path design for noise reduction

Fast operation, Energy saving

Applicable for reversible systems like heat pumps: bidirectional flow

Refrigeration Type R134A Electronic Expansion Valve
 

Specification:

Applicable refrigerants: R22, R134A, R404A, R407C, R410A, R507A etc.

Cooling Capacity: 3,5 to 105 kW (R22 Nominal Capacity)

Medium temperature: -30C to +70C (duty cycle rate below 50%)

Ambient temperature: -30C to +60C (duty cycle rate below 50%)

Relative humidity: below 95% RH

Ps: 4.5MPa (45 Bar)

Installation position: Coil upwards, valve rotor central axis within +/-15 versus vertical axis

500 steps (full stroke); 32 20 opening steps

Certifications: UL/CSA and declaration according to LVD or PED

  Model

   Port Size

 

Nominal Capacity

         (KW)

 

 

Max  W.P

Max  

O.P.D

Max 

R.O.P.D

(mm)

R22

R134a

R407C

R404A/R507A

R410A

(Mpa)

(Mpa)

(Mpa)

DPF(Q)1.3-01

1.3

3.5

2.7

3.5

2.5

4.2

4.2

3.43

≥2.1

DPF(Q)1.65-01

1.65

5.3

4.1

5.3

3.7

6.36

4.2

3.43

≥2.1

DPF(Q)1.8-01

1.8

7

5.4

7

4.9

8.4

4.2

3.43

≥2.1

DPF(Q)2.0-01

2

8.75

6.7

8.75

6.1

10.5

4.2

3.43

≥2.1

DPF(T)1.3-01

1.3

3.5

2.7

3.5

2.5

4.2

4.2

3.43

≥2.1

DPF(T)1.65-01

1.65

5.3

4.1

5.3

3.7

6.36

4.2

3.43

≥2.1

DPF(T)1.8-01

1.8

7

5.4

7

4.9

8.4

4.2

3.43

≥2.1

DPF(T)2.0-01

2

8.75

6.7

8.75

6.1

10.5

4.2

3.43

≥2.1

DPF(T)2.2-01

2.2

10.5

8.1

10.5

7.4

12.6

4.2

3.43

≥2.1

DPF(T)2.4-01

2.4

17.5

13.5

17.5

12.3

21

4.2

3.43

≥2.1

DPF(T)3.0-02

3

21

16.2

21

14.7

25.2

4.2

3.43

≥1.5

DPF(T)3.2-02

3.2

28

21.6

28

19.6

33.6

4.2

3.43

≥1.5

DPF(H)3.0-02

3

21

16.2

21

14.7

25.2

4.2

3.43

≥1.5

Refrigeration Type R134A Electronic Expansion Valve

Refrigeration Type R134A Electronic Expansion Valve

Folder

A file folder is a kind of folder that holds papers and money together for organization and protection. File folders usually consist of a sheet of heavy paper stock or other thin, but stiff, material which is folded in half, and are used to keep paper documents. Files may also contain other things like magazines, cased in music CDs, etc. sometimes mostly not used for any official use, rather used as normal storage in a home. They are often used in conjunction with a filing cabinet for storage. File folders can easily be purchased at office supply stores.

Portfolio Folder,Natural File Folders,Pocket Paper Folder,Pocket Presentation Paper Folder

Shenyang Meitu Artical Printing Co.,Ltd , https://www.meituartical.com