Plunger fuel pump structure based on the working principle

Fuel injection pump is the diesel fuel supply system, the most important piece, its performance and quality of diesel great influence, known as the "heart" of the diesel engine.


one. Function, requirement, type

Function: Increase diesel pressure, according to the working order of the engine, load size, timing and quantitative delivery of high pressure diesel fuel injector, and each cylinder equal pressure.

Claim:

(1) pump oil pressure to ensure the injection pressure and atomization quality requirements.

(2) The amount of fuel supply should be consistent with the exact number of diesel engine work required.

(3) Ensure that the diesel engine work order, accurate supply of oil within the prescribed time.

(4) adjustable fuel supply and fuel supply time, and ensure uniform fuel supply to each cylinder.

(5) The law of fuel supply should ensure that diesel combustion completely.

(6) start and end of fuel supply, agile, off the oil simply to avoid dripping.

Type: Automotive diesel injection pump according to their working principle can be divided into plunger-type injection pump, injection pump - injector and rotor dispensing pump three categories.

two. Piston pump pump oil principle

Piston pump pump mechanism consists of two sets of precision couplings:

Plunger and plunger sleeve is a pair of precision couplings that can not be interchanged after paired grinding, requiring high precision and smoothness and good wear resistance. The radial clearance is 0.002 ~ 0.003mm

Piston head cylindrical surface cut with a chute, and through the radial hole, the axial hole connected with the top, the purpose is to change the circulation of fuel supply; plunger sleeve system has into and back to the oil hole, both with the pump Low-pressure oil chamber connected to the body, the plunger set into the pump body, the positioning screw positioning.

Plunger head chute location, change the amount of fuel supply is also different. Outlet valve and the valve seat is also a pair of precision couplings, can not be swapped after grinding, with the gap of 0.01.

Outlet valve is a one-way valve, under the action of spring pressure, the upper conical surface of the valve is tightly matched with the valve seat. Its function is to cut off the high pressure oil pipe from the upper cavity of the plunger to prevent the oil in the high pressure pipe Inverted into the injection pump.

The lower part of the oil valve is cross-section, both to guide, but also through the diesel. Under the conical surface of the valve, there is a small cylindrical surface, called the vacuum ring, whose function is to quickly reduce the pressure of oil in the high-pressure tubing when the fuel supply ends, so as to avoid dripping oil at the orifice. When the ring falls into the valve seat, the upper volume increases rapidly, the pressure decreases rapidly, and the injection is stopped rapidly.

Pump oil principle

Work, the camshaft in the fuel injection pump camshaft and the role of the plunger spring, forcing the plunger up and down, reciprocating motion, thus completing the pump oil task, pump oil process can be divided into the following three stages.

Into the oil process

When the convex portion of the cam is rotated, the plunger moves downward due to the spring force. The upper space of the plunger (called the pump oil chamber) generates a vacuum. When the upper end of the plunger moves the plunger sleeve After the oil hole is opened, the diesel fuel filled in the upper body oil passage of the oil pump enters the oil pump chamber through the oil hole, and the plunger moves to the bottom dead center and ends in the oil inlet.

Oil supply process

When the camshaft turns to the convex portion of the cam, the plunger body is compressed and the plunger moves upward to compress the fuel. A part of the fuel flows back to the upper oil chamber of the injection pump through the oil hole. When the plunger top cover the upper edge of the sleeve into the oil hole, due to the small clearance between the plunger and sleeve (0.0015-0.0025mm) so that the top of the plunger pump chamber becomes a sealed oil chamber, the plunger Continue to rise, the pump oil chamber pressure rapidly increased, pump oil pressure> spring force of the valve + high pressure tubing remaining pressure, open the valve, high pressure diesel oil into the high pressure tubing through the injector Into the combustion chamber.

Return to the process

Plunger upward oil supply, when up to the plunger on the chute (stopping edge) and the sleeve connected to the oil return hole, the low pressure oil pump chamber and the plunger head of the hole and the radial hole And chute communication, a sudden drop in oil pressure, the oil valve in the spring force quickly closed, stop the fuel supply. After the plunger has to go up, when the convex part of the cam turn, under the action of the spring, the plunger down again. At this point they started the next cycle.

Conclusion: From the above discussion, the following conclusions can be drawn

â‘  plunger reciprocating total travel L is constant, determined by the cam's lift.

(2) The amount of fuel supplied by the plunger per cycle depends on the fuel supply stroke, and the fuel supply stroke is variable regardless of the camshaft control.

â‘¢ fuel supply start time does not change with the change of fuel stroke.

â‘£ Turn the plunger can change the fuel supply end time, thus changing the fuel supply.

Medical Instruments

We have a complete plastic consumables production line. Mold-making, injection molding and sterilization, all the procedures are done efficiently in our own factory. Precision molds, high quality raw material and advanced equipment to produce and perform quality testing with strict and comprehensive rules to ensure our products meet the highest quality and performance standards expected by the hospitals, research institutions and industrial, clinical laboratories that we supply.

• Excellent mold-making ability.

Our R&D team, with over 30 years` experiences, work with high quality mold-making equipment imported from Germany and professional mold analysis software that allow NEST to develop more precise molds.

• Injection molding in Class 10,000 and Class 100,000 clean rooms, with strict quality control.

10,764 ft2 Class 10,000 clean room and 32292 ft2 Class 100,000 clean room, all-electric high-speed injection molding machines imported from Japan, raw material which meet USP Class VI requirements. Production and quality control are performed strictly in accordance with corresponding SOP.

• Sterilization by electronic beam irradiation.

The Rhodotron TT200 electron accelerator which imported from the IBA company, Belgium. A world leader in the E-Beam sterilization industry. Sterilization process has been certified by the ISO 11137 quality system. Compared with sterilization by cobalt 60 or ethylene oxide sterilization, sterilization by electronic beam irradiation is more efficient and safer. It requires less time and will not produce any chemical residue.


medical1

Disposable Sampler

Transport Media & Swabs

Nest nylon flocked swabs provide optimum specimen collection because of their ability to collect more specimen at the collection site and to more rapidly release the entire sample specimen.

NEST disposable sampler is a collection and transport system which is used for aerobic, anaerobic and fastidious bacteria. In addition,

NEST disposable sampler can be used for nucleic acid test of bacteria.


medical2

Dry Saliva Collection Kits

Saliva Collection Kit

The product is used to collect high-quality DNA/RNA samples in the saliva.

The collection process is painless and won`t cause any injury or discomfort to the human body.

The collected samples can be used for various biological experiments such as enzymatic hydrolysis, PCR and next-generation sequencing and are widely used in the collection and preservation of specimens in hospitals, scientific research institutions and households.


News3

Disposable Intranasal Atomization Device

The device provides a painless and rapid absorption medication delivery option for non-invasive intranasal medication delivery. It improves safety for both caregivers and patients by avoiding needle-sticking injuries.

It is an atomizing device for drug administration intended to convert liquid preparations into atomized particles and spray on the surface of human body tissues (or organs) for full contact to maximize the administration effect. Meanwhile, the reasonable and effective self-destructive structure ensures that the product can only be used once to provide users with safe and hygienic products.


meidical4

Insulin Pen Injector

Wide application fields: Growth hormone, insulin, antibiotics, interferon, beauty products, biochemical emergency prevention, hemostatic pain, First aid for heart disease, detoxification, antipyretic analgesic, Anesthetic sedative class, etc.

Medical Instruments,Surgical Instruments,Doctors Instruments,Operating Room Instruments

Wuxi NEST Biotechnology Co.,Ltd , https://www.nest-biotech.com