Model NO.: LC-NA
Measuring Media: Liquid
Measuring Principle: Mechanics
Measurement Object: Closed Pipeline
Certification: DIN, ANS, CE, RoHS, ISO
Medium: High Viscosity Fluid Like Diesel: Signal: 4~20mA, Hart, RS485 Optional(Electric Coun
Sensor: Tube/Flange: Counter: Mechanical Type and Electrical Type
Trademark: U-Ideal
Transport Package: Wooden Case or Carton
Origin: China
HS Code: 90261000
1.     General Description
High accuracy positive displacement flowmeter for wide range of fluids including water, petroleum, solvent. The mechanical counter allows checking of total flowrates in the field. Output furnished flowmeter is also available optionally.Tianjin U-ideal Instrument oval flowmeter is suitable for viscous oils, ranging from hydraulic to light gear oils, eliminating any problems associated with changes in viscosity during operation. It also provides the advantage of positive displacement technology at a rotameter price. This flowmeter has a cost-effective design allowing for stress-free maintenance. The only wearable components are the oval gears and their axles, allowing the two-step rebuilding process to be easily accomplished in minutes with no necessary recalibration.
2.     Structure and Operation Principle
ÂU-ideal Oval meter is generally comprised of a flow transducer and a counter mechanism. The main part of the transducer is a measuring chamber which consists of a pair of oval wheels and a sealing coupling. The counter mechanism contains speed reduction gears, adjusting device, counter, and pulse transmitter etc.
Â
Â
In the measuring chamber, a pair of oval wheels and cover plate makes a crescent shape cavity which is used as a measuring unit. The oval wheels are rotated by the pressure difference in the inlet and outlet of the meter and drive the inlet liquid through the cavity to the outlet, each revolution of the oval wheels displaces fluid four time the volume of the cavity, the total revolutions of the oval wheels and the revolution rate will beÂ
Â
transferred to the mechanical counter, and the total liquid volume and instantaneous flow will be known by the pointer display and the roller integration. The attached signal generator converts the rotary axial angular shift to the pulse signal and then transmits it to the electrical indicator for remote integrated flow and instantaneous flow indication and control.
Â
Â
Chart 2: Permanent Magnet driving block diagram of Model LC flowmeter
Technical Parameter:
Â
Nominal diameter(mm) | Â Â 8-250 |
  Accuracy |   0.2% or 0.5% |
  Pressure loss |   0<1000Mpa<80kpa |
 Working pressure |  1.6,2.5,4.0,6.3,10,16,25,42Mpa |
Temperature range |  -20ºC-+300ºC |
Medium Viscosity | Â 0.1-1000Mpas |
 Ambient Condition | Temperature:-30ºC-+70ºC Humidity:5%-95% Pressure:86Kpa-106Kpa |
 Connection Flange | DIN or Can also be customized according to customer requirements |
Explosion-proof grade | Â The Ann IaII CT4, Explosion-proof :dII BT4 |
Nominal diameter(mm) |              Flow range  m3/h | ||
 |     Accuracy 0.5% |       Accuracy 0.2% | |
         8 |       0.05-0.5 |         0.1-0.3 | |
         10 |       0.1-0.6 |         0.2-0.6 | |
         15 |       0.16-1.6 |         0.5-1.5 | |
         20 |       0.25-2.5 |         0.8-2.4 | |
         25 |       0.6-6.0 |           2-6 | |
         40 |       1.6-16 |          5-15 | |
         50 |       2.5-20 |          6-18 | |
         80 |        6-48 |         12-48 | |
        100 |        8-80 |         20-60 | |
        150 |       25-200 |         60-180 | |
        200 |       45-360 |        100-300 | |
        250 |       80-500 |        150-450 |
Material: Stainless steel 304/316,Cast steel ,cast iron
Â
Gear Pump,Water Centrifugal Pump Co., Ltd. , http://www.nschemicalpump.com